Test
Thermo Scientific™ TraceGOLD TG-XLBMS GC Columns offer a low polarity, low bleed column suitable for a wide range of applications.
Max. Temperature | 340/360°C |
---|---|
Stationary Phase | TraceGOLD™ TG-XLBMS |
Polarity | Low-Polar |
Separate ethane, ethylene and acetylene consistently with the intermediate polarity PLOT column with essentially no particle release.
Max. Temperature | Up to 250°C |
---|---|
Stationary Phase | TracePLOT™ TG-BOND Q+ |
Polarity | Mid-Polar |
For Use With (Application) | GC for the Separation of Ethane, Ethylene, and Acetylene to Baseline |
Choose these colums that feature a popular GCMS phase for many applications.
Stationary Phase | Trace™ TR-5 MS |
---|---|
Polarity | Non-Polar |
USP Type | G27, G36 |
Used for traditional general purpose applications, where a non-polar column is required.
Max. Temperature | -60°C to +300°C (isothermal or programmed) |
---|---|
Type | Capillary GC |
Packing Material | Poly(dimethyl siloxane) |
Diameter (Metric) Inner | 0.53 mm |
Polarity | Non-Polar |
Material | Fused Silica |
For Use With (Application) | Gas Chromatography (GC) |
Film Thickness | 1.5 μm |
USP Type | G1, G2, G9 |
Product Line | SPB |
Use Thermo Scientific™ TracePLOT TG-BOND Alumina GC Columns for linear and quantitative analysis of polar unsaturated hydrocarbons.
Max. Temperature | Up to 200°C |
---|---|
Stationary Phase | TracePLOT™ TG-BOND Alumina |
For Use With (Application) | Polar Unsaturated Hydrocarbons Analysis,GC for Unsaturated Hydrocarbon Isomers,Linear and Quantitative Analysis of Polar Unsaturated Hydrocarbons |
Use these thermally stable TraceGOLD TG-PAH GC columns for fast analysis of regulated polycyclic aromatic hydrocarbons (PAHs) in complex food and environmental samples.
Stationary Phase | TraceGOLD™ PAH |
---|---|
For Use With (Application) | Gas Chromatography (GC) |
Product Line | TraceGOLD |
Analyze a wide range of polar compounds with this low-bleed, general purpose, high polarity GC column.
Stationary Phase | Trace™ TR-WAX |
---|---|
Polarity | Polar |
USP Type | G16, G20 |
Perform fast, highly sensitive analysis of multi-class contaminants with Thermo Scientific™ TraceGOLD™ TG-Contaminants GC columns.
Use a glass column for applications where high inertness is required, such as for the analysis of active analytes. All glass columns undergo a proprietary high temperature silanization to ensure inertness.
An economical metal column should be used for less demanding applications where the inertness of glass is not required. This column is of a general configuration, and can be carefully bent to fit most instruments.
Use a glass column for applications where high inertness is required, such as for the analysis of active analytes. All glass columns undergo a proprietary high temperature silanization to ensure inertness.
An economical metal column should be used for less demanding applications where the inertness of glass is not required. This column is of a general configuration, and can be carefully bent to fit most instruments.
An economical metal column should be used for less demanding applications where the inertness of glass is not required. This column is of a general configuration, and can be carefully bent to fit most instruments.
Type | Packed GC |
---|---|
Packing Material | HayeSep N |
Diameter (English) Outer | 0.125 in. |
Diameter (Metric) Inner | 2.1 mm |
Material | Stainless Steel Column |
For Use With (Application) | Gas Chromatography (GC) |
An economical metal column should be used for less demanding applications where the inertness of glass is not required. This column is of a general configuration, and can be carefully bent to fit most instruments.
Good for separations of heterocyclic amines.