Fisherbrand™ Traceable™ Conductivity/TDS Meter Pen
Easy-to-use, waterproof conductivity/TDS meter designed for routine analysis and quality control. Simply turn on, insert, and simultaneously read result and temperature.

Fisherbrand™ accumet™ Basic AB330 Conductivity/TDS/Salinity Benchtop Laboratory Meter
Ideal for daily conductivity, TDS and salinity testing of your routine laboratory samples, the accumet™ Basic AB330 Benchtop Meter provides essential functions needed without complicated functions at a budget-friendly price.
Memory | Non-volatile |
---|---|
Cell Constant | 0.1 to 10 |
Measurement Modes | Conductivity with Temperature,TDS with Temperature,Salinity with Temperature |
Temperature (Metric) Reference | 15, 20, 25 or 30°C |
Temperature Coefficient | 0 to 10 %/°C |
TDS Factor Range | 0.4 to 1 |
Range (Salinity) | 0 to 80 ppt |
Data Management Details | Printed or CSV Format |
Temperature Compensation | Linear |
Display Type | 5 in. LCD |
Accuracy (Salinity) | ±1% Full Scale |
Resolution (Salinity) | 0.01, 0.1 ppt |
Voltage | 100/240 V |
Accuracy (Conductivity) | ±1% Full Scale |
Data Points | 500 Points |
Inputs | Conductivity, ATC |
Accuracy (Temperature) | ±0.3°C (±0.5°F) |
Calibration Points (Conductivity) | 84 μS, 1413 μS, 12.88 mS, 111.8 mS |
Temperature Accuracy | ±0.3°C, ±0.5°F |
Stability | Indicator Icons |
Warranty | 3 Years |
Resolution (Conductivity) | 0.01, 0.1, 1 μS; 0.01, 0.1 mS |
Range (Conductivity) | 0 μS to 500 mS |
AC Adapter | Universal Power Adapter |
Resolution (TDS) | 0.01, 0.1, 1 ppm; 0.01, 0.1 ppt |
Calibration | Conductivity, TDS, Salinity, Temperature |
Calibration Points | 1 to 5 (Conductivity), 1 to 5 (TDS), 1 (Salinity), 1 (Temperature) |
Accuracy (TDS) | ±1% Full Scale |
IP Rating | IP54 |
Data Logging | Automatic with Auto-read and Timed Modes, Manual with Continuous Mode |
Model | AB330 |
Outputs | Port for Computer or Printer |
Frequency | 50/60 Hz |
Backlight Option | Yes |
Resolution (Temperature) | 0.1°C (0.1°F) |
Temperature Range (Metric) | -5°C to +105°C |
Thermo Scientific™ Orion Star™ A212 Conductivity Benchtop Meter
Reliably measure conductivity, TDS, salinity, resistivity and temperature with this conductivity benchtop meter for advanced lab analysis.

Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) |
---|---|
Range (Resistivity) | 2 ohm to 100.0 megohm |
Memory | Non-volatile memory preserves data log, calibration log and meter settings |
Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update |
Measurement Modes | Conductivity,TDS,Salinity,Resistivity with Temperature |
Power Supply | Universal AC adapter (included) or 4 AA batteries (sold separately) |
Battery Life | 800 hr. |
Data Management Details | Transfer single, range or all data points to printer or computer |
Display Type | Graphic LCD with Backlight |
Data Points | 2000 with date and time stamp |
Certifications/Compliance | CE, TUV 3-1, FCC Class A |
Temperature Probe Calibration | 1 point temperature offset calibration |
Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
Warranty | 3 Year Meter |
Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits |
Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm |
Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
Battery Type | 4 x AA (sold separately) |
Relative Humidity Range | 5 to 85%, non-condensing |
Dimensions (L x W x H) | 24 x 18 x 11 cm (9.5 x 7.1 x 4.3 in.) |
Accuracy (TDS) | 0.5% of reading ±1 digit |
Temperature Selection | Manual or automatic with ATC temperature probe |
Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
Outputs | USB, RS232 |
Backlight Option | Yes, selectable |
Compatible Probes | 2-cell or 4-cell conductivity sensors with built-in temperature |
Methods | 10 per channel with password protection |
Cell Constant | 0.001 to 199.9cm-1 |
Temperature (Metric) Reference | 5, 10, 15, 20, 25°C |
Channels | 1 |
TDS Factor Range | Linear (0.02 to 9.99) |
Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt |
Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off wit |
Accuracy (Salinity) | 0.5% of reading ±1 digit |
Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging |
Inputs | 8 pin MiniDIN (conductivity sensor with built-in temperature), stirrer input (stirrer probe) |
Accuracy (Temperature) | ±0.1°C |
Weight (Metric) | 0.9 kg |
Calibration Points (Conductivity) | 5 |
Temperature (English) Operating | 41°F to 113°F (ambient) |
Resolution (Resistivity) | 1 ohm or 0.1 megohm, auto ranging |
Accuracy (Resistivity) | 0.5% of reading ±1 digit |
AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. 1010003) |
Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits |
Calibration | Conductivity with calibration editing option and temperature |
Alarm Output | High/low limit alarm, calibration due alarm |
IP Rating | IP54 |
Model | Orion Star A212 Conductivity/TDS/Salinity/Resistivity/Temperature Benchtop Meter |
Weight (English) | 2 lb. |
Resolution (Temperature) | 0.1°C (0.1°F) |
Temperature (Metric) Operating | 5°C to 45°C (ambient) |
Temperature Range (Metric) | -5°C to +105°C |
Mettler Toledo™ FiveGo™ F3 Conductivity Meters
Portable meter provides reliable and high quality conductivity measurements with simple click of a button
Memory | 200 measurements |
---|---|
Range (Conductivity) | 0.00 μS/cm to 200 mS/cm |
Languages | Chinese, Chinese (TW), Croatian, Czech, Danish, Dutch, English (GB), English (US), French, German, Hungarian, Indonesian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese (BR), Russian, Slovak, Slovenian, Spanish, Swedish, Thai, Turkish, Vietnamese |
Calibration | One point calibration with three predefined standards |
Channels | 1 |
Dimensions (L x W x H) | 18.8 x 7.7 x 3.3 cm (97.4 x 3 x 1.3 in.) |
Temperature Compensation | Linear: 0.00%/°C to 10.00%/°C, reference temperature: 20° and 25°C |
Display Type | LCD |
Accuracy (Conductivity) | ±0.5% of the measured value |
Weight (English) | 0.5 lb. |
Resolution (Temperature) | 0.1°C |
Temperature Range (Metric) | 0°C to 100°C |
Inputs | LTW 7-pin |
Accuracy (Temperature) | ±0.5°C |
Weight (Metric) | 0.26 kg |
Fisherbrand™ Traceable™ Expanded Range Conductivity Meter
Ideal for checking the purity of water from stills, deionizers, and reverse osmosis, testing laboratory glassware rinsing, measuring total dissolved solids, and making solutions.

Fisherbrand™ Traceable™ Dual-Display Conductivity Meter
Measures conductivity and temperature; includes NIST™ traceability certificate.

Fisherbrand™ Traceable™ Conductivity Meter Pen
Easy-to-use, waterproof conductivity meter designed for routine analysis and quality control. Simply turn on, insert, and simultaneously read result and temperature.