Hamilton Company
Browse a range of Hamilton Company liquid handling, sample management, syringes, and other products to support your HPLC and other analytical testing needs.
Filtered Search Results

Hamilton™ 700 7000/1700 1000 Series Microliter™/Gastight™: KH Termination
Syringes have built-in Chaney Adapters

Needle Point Number | 3 |
---|---|
Length (Metric) | 70 mm |
Length (English) | 2.75 in. |
Quantity | Ea. |
Min. Temperature (English) | 50°F |
Material | Borosilicate Glass (Barrel),Stainless Steel (Plunger) |
Max. Temperature (Metric) | 115°C |
For Use With (Application) | Designed for liquid sampling to achieve the highest level of accuracy and precision possible, for use with HPLC injection valves and for sample pipetting |
Max. Pressure | 6000 psi |
Product Type | Microliter Syringe |
Connection Type | Knurled Hub |
Max. Temperature (English) | 239°F |
Needle Point Style | Blunt |
Length (English) Needle | 2.75 in. |
Autoclavable | Autoclavable |
Min. Temperature (Metric) | 10°C |
Hamilton™ Kel-F Hub Sharp Non-Coring Needles (Luer Lock)
Kel-F hub (KF) needles can be used with Luer Tip (LT) and PTFE Luer Lock (TLL) syringes and connectors. Standard needle length is 2 in. (51 mm). Custom lengths and point styles are available.

For Use With (Equipment) | Luer-tip and PTFE Luer-lock Syringes and Connectors |
---|---|
Product Type | Kel-F Hub Needle |
Material | Stainless Steel |
Length (English) Needle | 2 in. |
Autoclavable | Not Autoclavable |
Hamilton™ Metal Hub Sharp Non-Coring Needles (Luer Lock)
Metal hub (nickel plated brass) needles can be used with TLL syringes and LT or TLL connectors. Needles are 304 stainless steel (sst.). Standard needle length is 2 in. (51mm). Custom needle lengths and point styles are available.

Product Type | Replacement Needle |
---|---|
Needle Point Style | Sharp, Bevel, Curved |
Length (English) Needle | 2 in. |
Length (Metric) | 17.78 cm |
---|---|
Product Type | Cleaning Wire |
Length (English) | 7 in. |
Material | Tungsten |
Hamilton™ PRP™-C18 Reversed-Phase HPLC Columns: Stainless Steel
Designed to provide high-efficiency, reversed-phase separations over an extended column life in nearly any mobile phase or pH
Pore Size | 100 Å |
---|---|
Type | Column |
Stationary Phase | PRP-C18 |
Phase | Reversed Phase |
For Use With | LC/MS Separation |
Column Type | Reversed Phase |
Mobile Phase Compatibility | pH 1 to 13, 0 to 100% aqueous, organic modifier |
Material | Stainless Steel |
Max. Pressure | 5000 psi (345 bar) |
USP Type | L21 |
Hamilton™ 1700 Series Gastight™ Syringes: Cemented Needle (N) Termination
Gastight version of the original 700 series syringes, ideal for dispensing volumes from 1 up to 500μL. ideal for dispensing both liquids and gases and have a precision-machined PTFE plunger tip which creates a leak-free seal.
Hamilton™ 1700 Series Gastight™ Syringes: LTN Termination
Gastight version of the original 700 series syringes, ideal for dispensing volumes from 1 up to 500μL
Diameter (English) Inner | 0.12 in. |
---|---|
Length (Metric) | 51 mm |
Volume (Metric) | 500 μL |
Length (English) | 2 in. |
Diameter (Metric) Inner | 3.26 mm |
Quantity | Ea. |
Min. Temperature (English) | 50°F |
Material | Borosilicate Glass (Barrel),PTFE (Tip),Stainless Steel (Plunger) |
Max. Temperature (Metric) | 50°C |
For Use With (Application) | Ideal for dispensing both liquids and gases, useful for samples with dissolved or suspended molecules |
Max. Pressure | 700 psi |
Diameter (Metric) Inner Needle | 0.41 mm |
Product Type | Gastight Syringe |
Diameter (Metric) Outer | 7.75 mm |
Connection Type | Luer Tip, Cemented |
Max. Temperature (English) | 122°F |
Diameter (English) Outer | 0.3 in. |
Model | 1750 |
Diameter (Metric) Outer Needle | 0.72 mm |
Length (English) Needle | 2 in. |
Autoclavable | Not Autoclavable |
Min. Temperature (Metric) | 10°C |
Needle Gauge | 22 G |
Diameter (English) Outer Needle | 0.02 in. |
Diameter (English) Inner Needle | 0.01 in. |
Hamilton™ 700 7000/1700 1000 Series Microliter™/Gastight™: TLL Termination
Syringes have built-in Chaney Adapters
Needle Point Number | No Needle Included |
---|
Hamilton™ 1800 Series Gastight™ Fixed-Needle Syringes
Reinforced plunger version of the 1700 series syringes is ideal for dispensing volumes from 1 μL up to 500 μL.
Needle Point Number | 2 |
---|---|
Quantity | 1/Pk. |
Min. Temperature (English) | 50°F |
Material | Borosilicate Glass (Barrel),PTFE (Tip),Stainless Steel (Plunger) |
Max. Temperature (Metric) | 50°C |
For Use With (Application) | Dispensing volumes from 1μL up to 500μL |
Max. Pressure | 1000 psig (68.9 bar) |
Product Type | Gastight, Cemented Needle |
Connection Type | Cemented |
Max. Temperature (English) | 122°F |
Needle Point Style | 2 |
Length (English) Needle | 2 in. |
Autoclavable | Not Autoclavable |
Min. Temperature (Metric) | 10°C |
Hamilton™ 1700/1000 Series Gastight™ Instrument Syringes: C Termination
Syringes are designed to fit into, or with, various different instruments such as the MICROLAB™ 500 and MICROLAB 1000
Needle Point Number | No Needle Included |
---|---|
Product Type | Gastight Syringe |
Connection Type | ChemSeal |
Max. Temperature (English) | 239°F |
Quantity | Ea. |
Min. Temperature (English) | 50°F |
Material | Borosilicate Glass (Barrel),PTFE (Tip) |
Max. Temperature (Metric) | 115°C |
For Use With (Application) | For dispensing volumes from 100μL up to 100mL |
Autoclavable | Autoclavable |
Hamilton™ 1800 Series Gastight™ Removable-Needle Syringes
Reinforced plunger version of the 1700 series syringes is ideal for dispensing volumes from 1 μL up to 500 μL.
Needle Point Number | 2 |
---|---|
Connection Type | Removable |
Max. Temperature (English) | 239°F |
Needle Point Style | Sharp, Bevel, Curved, Non-coring |
Quantity | Ea. |
Min. Temperature (English) | 50°F |
Material | Borosilicate Glass (Barrel),PTFE (Tip),Stainless Steel (Plunger) |
Length (English) Needle | 2 in. |
Max. Temperature (Metric) | 115°C |
For Use With (Application) | Dispensing volumes from 1μL up to 500μL |
Autoclavable | Autoclavable |
Min. Temperature (Metric) | 10°C |
Diameter (English) Inner Needle | 0.005 in. |
Hamilton™ Replacement Needles for Agilent 7673, 7683, 7693, and 6850 ALS GC Syringes
Can be used with removable (RN)-style syringes that are 100 μL and smaller. These needles are manufactured for use with Agilent Instrumentation 7673-7683, 6850, 7670, 7671, and 7672 ALS models. Custom lengths and point styles are available.
Product Type | Replacement Needle |
---|---|
Needle Point Style | Removable AS |
Length (English) Needle | 1.69 in. |
Autoclavable | Autoclavable |
Hamilton™ 1700 and 1000 Series Gastight™ SampleLock™ Syringes, 22 Gauge
Hamilton SampleLock syringes allow you to collect, store, transport and analyze liquid or gaseous samples without the danger of evaporative loss or environmental contamination.
Needle Point Number | 2 |
---|---|
Quantity | Ea. |
Min. Temperature (English) | 50°F |
For Use With (Application) | To collect, store, transport and analyze liquid or gaseous samples without the danger of evaporative loss or environmental contamination |
Diameter (Metric) Inner Needle | 0.41 mm |
Product Type | General Purpose Syringe |
Connection Type | Sample Lock, Removable |
Needle Point Style | Sharp, Bevel, Curved, Non-coring |
Diameter (Metric) Outer Needle | 0.72 mm |
Length (English) Needle | 2 in. |
Autoclavable | Not Autoclavable |
Min. Temperature (Metric) | 10°C |
Needle Gauge | 22 G |
Diameter (English) Outer Needle | 0.02 in. |
Diameter (English) Inner Needle | 0.01 in. |
Hamilton™ Luer Lock Metal Hub Needles, 10 gauge, Metal Hub NDL, 2 in., point style 5
Luer Lock is an industry standard tapered termination utilized by most syringe manufacturers including medical Hypodermic syringes. Luer Lock needles are common because their design is controlled by a series of universal standards which guarantees compatibility between manufacturers.
Hamilton™ Replacement Needles for Valco VISF-1 Injection Valve Syringes
Replacement needles for Valco VISF-1 injection valve syringes
For Use With (Equipment) | Valco VISF-1 Injection Valve Syringes |
---|---|
Product Type | Replacement Syringe Needle |
Diameter (Metric) Outer | 0.72 mm |
Diameter (English) Outer | 0.028 in. |
Needle Point Style | Removable Square/Blunt |
Length (English) Needle | 0.75 in. |
Autoclavable | Autoclavable |